The Ultrasonic Contact Impedance hardness tester is used for measuring the hardness value of small items, objects with a thin wall, complex form, and to measure the hardness of surface hardened layers.
Built-in camera allows user to picture of testing object and mark tested area with corresponding hardness value.
The device has PC software with a comfortable and intuitive interface.
UCI method for the hardness testing
The UCI hardness measuring method complies to ASTM A1038.
The ultrasonic contact impedance (UCI) probe is purposed to be used for hardness measuring in the case of the testing area minimal thickness (from 1 mm), objects of complex surface shape, and for measuring surface hardened layers hardness.
This method is very fast and easy: place the probe on the tested object surface, press the probe with the required effort to the surface and save the hardness value, shown on the display of the device. Small size diamond indenter allows measuring hardness value of all items, which are thicker than 1 mm. The UCI method of hardness testing is the least destructive because the hardness tester with UCI probe leaves much smaller prints (imprints) than the majority of bench hardness tester would. That’s why a portable hardness tester with UCI probe is the best choice.We have the CE certificate of conformity for Portable UCI Hardness Tester.
Features
• Hardness measurement of any mass products with a thickness more than 1 mm – inaccessible to the dynamic (Leeb) hardness testers (small parts, thin-walled structures, pipes, tanks, steel sheets, articles of complex shape, hardness control of metal coatings, etc.)
• Measuring the hardness of the surface hardened layer
• Small imprint after measuring (mirror surfaces of shafts necks, blades, gear teeth, etc.)
• Wide range of hardness testing
• Various measurement modes
• Calibration of any scale in any range
• Convenience and ease for measurement
• Optimized number of buttons
• Large full color graphic display with bright back-lighting
• Calibrations stored in memory of probe
• Extended temperature range (frost, down to – 40°C)
• Internal memory and communication with PC
• New, intuitive menu with tips on the buttons
• Optional wireless mini printer
• Water resistant case
• Rubber protected bumper
• Has different operating modes:
Graph – the mode of building of graph
Histogram – the mode of building of histogram
Statistics – the mode of statistic
Smart – the mode of filtering of incorrect measurements
Load |
Advantage or Benefit |
Typical Applications |
50N |
Considered to be the Universal type |
Induction or carburized machined parts, e.g.. |
10N (2.2lbf) |
Load is easy to apply; provides |
Ion-nitrided stamping dies and molds, forms, |
Specification
UCI probe types |
1kgf (10N) 2.2 lbf, 5kgf (50N) 11lbf, 10kgf (98N) |
Measuring Range |
HV:230~940; HRC:20~70; HB:90~650. Tensile strength, MPa 370~1740 |
Measuring Accuracy |
HV:±3%HV; HRC:±1.5%HRC; HB:±3%HB |
Indenter |
Diamond Indenter (UCI) |
Measuring Direction |
Any direction 360° |
Data Storage |
Limited only by the memory card |
Communication |
Upload data to PC and export as a spreadsheet (USB cable and software included ) |
Hardness Scale |
HRC, HB, HV, HRB, HS, HL, MPa |
Materials |
- Ultrasonic (UCI) probe – pre-calibrated for steel. |
|
-Additional custom materials for calibration. |
Data display |
Load applied/contact (UCI), Single test result, Max, Min, Average of |
|
tests, Number of tests, Deviation, Var. coeff, Histogram, Signal and |
|
Smart Mode (Filter of incorrect measurements). |
Indication |
Color LCD display (320×240) |
Operating Environment |
Temperature:-20°C~40°C; Humidity: 30%~80%R.H. |
Power Supply |
DC 4,5V (3 pc batteries AA) |
Instrument Dimensions |
160x75x30mm |
Net Weight |
Approx. 0.3kg (Without probe) |
Battery life |
Approx. 10 hours. |
Quality First, Safety Guaranteed